0% Question 1 of 10 1. A UPS ensures seamless and bumpless transfer of power on a power failure?A.TrueB.FalseQuestion 1 of 10Question 2 of 10 2. When troubleshooting an uninterruptable power supply check?A.LED status indicators on the front of the UPSB.Input voltages C.Output voltagesD.All of the above Question 2 of 10Question 3 of 10 3. When installing receptacles for unit equipment for emergency lighting it should be installed as per which option below?A.Above 3m from grade and 2m from the unit equipment B.Not less than 2.5m above the floor and not more than 1.5m from the unit equipmentC.Wherever practical D. Not less than 1.5m above the floor and not more than 1.5m from the unit equipment Question 3 of 10Question 4 of 10 4. When batteries are used as a source of emergency power they shall be kept at least 65% charged?A.TrueB.FalseQuestion 4 of 10Question 5 of 10 5. How will an emergency power supply be activated when the normal power supply is disrupted?A. A manual transfer switch operated by authorized personnel B.A manual transfer switch operated by anyone C.By remote control switching D.Automatic transfer equipment Question 5 of 10Question 6 of 10 6. When you have electrical supplies that are interconnected, what should be installed at the supply authority disconnecting means?A. The contact information of the maintenance contractor who installed the standby generator B.Warning notice of an interconnected system and a single line, permanent, legible diagram of the interconnected systemC.Warning notice of an interconnected system and the maximum load that can be fed during loss of power of the AC mainsD.Name of a contact person with details on how to contact the single point of contact in the event of emergencyQuestion 6 of 10Question 7 of 10 7. Where should the disconnecting means for a large wind turbine be located?A. Within 5m of the base of the tower B. Within 3m of the base of the towerC. At the base of the tower D. In the Electrical room located not more than 20m from the base of the towerQuestion 7 of 10Question 8 of 10 8. Flexible cords suitable for extra-hard usage can be used to interconnect solar panels within an array?A.TrueB.FalseQuestion 8 of 10Question 9 of 10 9. A wind system with a rated power output of 120KW is defined as what type of system?A.Small wind system B.Medium wind systemC.Large wind systemD.Custom wind systemQuestion 9 of 10Question 10 of 10 10. The max distance a unit equipment receptacle can be located from the unit equipment is 150mm.A.TrueB.FalseQuestion 10 of 10 Loading...
Question 1 of 10
Question 2 of 10
Question 3 of 10
Question 4 of 10
Question 5 of 10
Question 6 of 10
Question 7 of 10
Question 8 of 10
Question 9 of 10
Question 10 of 10